| Key Information » Model No. 6-RAH-RS SS |
| Base Material: |
Stainless |
| Size: |
Deck base size is 12"x16". |
| Max Pipe Size: |
6" inside diameter and 8 1/2" outside diameter. |
| Max Pipe Clearance: |
A low of 2" to a high of 7" off the roof. |
| Max Load Weight: |
Weight should be evenly distributed, on both restraint support and non-penetrating supports. |
| Spacing: |
A. It is recommended that a structural analysis of the restraint support(s) based upon proposed project layouts be performed to accurately determine the code level site-specific frame reactions. This will generally significantly reduce the magnitude of frame loads to the supporting structure, and minimize the need for reinforcement or additional framing.
B. Maximum restraint support spacing indicated are based upon support capacity, and not upon the supported component capacity. Support spacing must be determined by the specifier to meet the requirements of the supported component code standard maximum longitudinal and lateral support spacings.
C. The capacity of the supporting structure and method of restraint support attachment (i.e. bolting) must be verified by the structural engineer of record. Additional structural framing and/or local reinforcement may be required in order to support the restraint frame base reactions. |
| |
|